top of page

04. Ultrasonic Sensor

04. Ultrasonic Sensor

It is a device that is installed on each parking surface of a parking lot that requires parking surface management and detects the presence or absence of a vehicle using ultrasonic waves to provide a signal to the sensor controller.

1) Ultrasonic frequency: 40 kHz
2) Input voltage: DC24V
3) Current consumption: 8mA
4) Power consumption: 0.2W
5) Communication method: Power line communication (non-polar two-way)
6) Operating temperature: -20 degrees to 60 degrees
7) Humidity: 90% or less
8) Sensor type: Transmission/reception detachable
9) Maximum number of nodes: 127

· Induction of vacant seats and parking spaces only/information on the presence or absence of tolerances
· Real-time parking surface parking status management and graphs of various parking lots
· Easy installation and maintenance without the need for a separate communication line by adopting a non-polar two-wire DC power line communication method.

Model: ST-USS

bottom of page